Can we talk about why everyone mounts motion sensors at 7 feet when 6'6" catches way more walkers
I've been installing systems around Dayton for 11 years and I still see guys screwing PIRs at 7 feet out of habit, then blaming the sensor when pets trip it or the far corner of the room stays dead. Back in the old days with the big passive cans we had no choice, but the newer units have a way wider pattern and 6'6" puts the detection zone right where a person's body mass actually crosses it. Last month I re-hung a sensor in a garage from 7 feet down to 6'6" and the customer's "faulty" zone calls stopped completely. Measure your walk test pattern at both heights on your next install and tell me I'm wrong.
Read a Honeywell app note that said their newer PIRs are spec'd for 6'6" to 7'6" mounting, so both heights fall in range but the lower end covers the walk test better. Pulled one down to 6'6" in my own hallway and the pet calls dropped off.